ukflag (44) (0) 207 355 3555
usflag (1) 941 925 9730
 
 
 
 
 
 
 
 
 
 
 
     
     
     
astroscan 5335

Astroscan 5335 technical specifications (for both 5335 and 5335-S)

Standard Features

Sensitivity
40 AWG Guaranteed

Resolution
1mm both vertical and horizontal

Penetration
12mm steel guaranteed

Contrast Sensitivity
At least 20 levels visible as measured by a step wedge, 4096 gray level

Image display
Colour, organic, inorganic, black & white, reverse monochrome, and pseudo color

Dose per inspection
0.1mR typical

Tunnel Opening
530mm (21") wide by 350mm (14") high

Conveyor Speed
0.23m per sec (45’ per min)

Power Requirements
115-125 VAC, 50-60 Hz
230-240 VAC, 50-60Hz

Density Threat Alert
Programmable Levels

UPS (Uninterrupted power supply)
Shuts down computer 2 minutes after power failure

Automatic Image Archiving
Up to 20,000 images in a rotating buffer

Manually save Image
In windows format to view on personal computers or laptops

Print Image
Any user’s provided printer configurable by Win 2000

X-Ray Generator

Voltage

Astroscan 5335: 100 kVp Constant potential tube operation at 90kV
Astroscan 5335-S: 160 kVp Constant potential tube operation at 90kV

Tube Current
0.7mA

Cooling
Sealed oil bath

Duty Cycle
100%

Beam Direction
Upward Vertically

Optional Accessories


Flat Panel LCD Monitor
Flootmat
Extended Conveyor (UK Specifications) or Accessories
Screener Training Program
Networking System
Threat Image Projection (TIP)
Networking Tip
Remote Workstation
External Power Generator

X-Ray Detector
1024 photodiodes in an "L" Shapped configuration

Physical Specifications

Weight
Approximately 350 Kg (770lbs)

Shipping Weight
Approximately 400 Kg (880lbs)

Processor
A t least a Pentium-IV, 3.0 Ghz with hyperthreading technology, 512MB RAM, Advanced Video Graphics Card with 128MB RAM, 40GB Hard Disk

Video display
19" SVGA high resolution, low radiation, ergonomic, flicker free flat monitor

Health and safety
all x-ray systems are certified to be in full compliance with all international radiation safety requirements and external emissions limits. typical leakage radiation is less than 0.1 mR/hr compared to a maximum of 0.5 mR/hr permitted.

Film safety
guaranteed for high-speed films up to ISO1600

Operational standards

complies with all published international standards including the U.S. federal aviation administration standards, “use of x-ray systems” (federal standards 14 CFR 108.17 and 14 CFR 129.26).

Click here to print this page