ukflag (44) (0) 207 355 3555
usflag (1) 941 925 9730
 
 
 
 
 
 
 
 
 
 
 
     
     
     
astroscan 6545

astroscan 6545 technical specifications

tunnel opening
25.6" wide (650mm) x 17.7" high (450mm)

sensitivity
36 AWG guaranteed using new ASTM F-792

spatial resolution
1mm using new ASTM F-792 test bag

penetration
22 mm steel guaranteed using new ASTM F-792 test Bag

contrast sensitivity
IT-H4 guaranteed IT-H3 typical, 4096 gray scale levels

dose inspection
0.1 mR typical

material discrimination
Dual-Energy HI-MAT + Organic=Orange, Inorganic=Blue, Mixed=Green

power requirements
110 - 120 VAC (6 Amps. max) 220 – 240 VAC (3 Amps.)

x-ray generator

voltage
160 kVp tube, operating at 140 kVp

tube current
0.8mA

cooling
sealed oil bath

duty cycle
100%

beam direction
vertically upward

x-ray detector
1280 photo diodes in an “L” shaped configuration

environmental conditions

operating temperature
-17°C- 50°C

storage temperature
-40° C to 70°C

humidity
Less than 95%

computer specifications

minimum configuration
pentium-IV, 3 GHZ, Ram: 256Mb, HDD: 40 GB, CD ROM, FDD: 1.44Mb

video displays
dual 19” SVGA high resolution, low radiation, flicker free flat monitors

physical specifications

length
87.49 inches (222.4 mm)

height
50.50 inches (1282.7mm)

width
32.38 (822.3mm)

weight
approximately 990lbs (450 Kgs)

conveyor speed
45 feet per minute(13.5 meters per minute)

conveyor capacity
220lbs (100kg)

construction
Steel frame on casters

health and safety

all x-ray systems are certified to be in full compliance with all international radiation safety requirements and external emissions limits. typical leakage radiation is less than 0.1 mR/hr compared to a maximum of 0.5 mR/hr permitted.

film safety
guaranteed for high-speed films up to ISO1600

operational standards
complies with all published international standards including the U.S. federal aviation administration standards, “use of x-ray systems” (federal standards 14 CFR 108.17 and 14 CFR 129.26)

Click here to print this page