astroscan
6545 technical specifications
tunnel opening
25.6" wide (650mm) x 17.7" high (450mm)
sensitivity
36 AWG guaranteed using new ASTM F-792
spatial resolution
1mm using new ASTM F-792 test bag
penetration
22 mm steel guaranteed using new ASTM F-792 test Bag
contrast sensitivity
IT-H4 guaranteed IT-H3 typical, 4096 gray scale levels
dose inspection
0.1 mR typical
material discrimination
Dual-Energy HI-MAT + Organic=Orange, Inorganic=Blue, Mixed=Green
power requirements
110 - 120 VAC (6 Amps. max)220 – 240 VAC (3 Amps.)
x-ray generator
voltage
160 kVp tube, operating at 140 kVp
tube current
0.8mA
cooling
sealed oil bath
duty cycle
100%
beam direction
vertically upward
x-ray detector
1280 photo diodes in an “L” shaped configuration
environmental conditions
operating temperature
-17°C- 50°C
storage temperature
-40° C to 70°C
humidity
Less than 95%
computer specifications
minimum configuration
pentium-IV, 3 GHZ, Ram: 256Mb, HDD: 40 GB, CD ROM, FDD: 1.44Mb
video displays
dual 19” SVGA high resolution, low radiation, flicker free
flat monitors
physical specifications
length
87.49 inches (222.4 mm)
height
50.50 inches (1282.7mm)
width
32.38 (822.3mm)
weight
approximately 990lbs (450 Kgs)
conveyor speed
45 feet per minute(13.5 meters per minute)
conveyor capacity
220lbs (100kg)
construction
Steel frame on casters
health and safety
all x-ray systems are certified to be in full compliance with all
international radiation safety requirements and external emissions
limits. typical leakage radiation is less than 0.1 mR/hr compared
to a maximum of 0.5 mR/hr permitted.
film safety
guaranteed for high-speed films up to ISO1600
operational standards
complies with all published international standards including the
U.S. federal aviation administration standards, “use of x-ray
systems” (federal standards 14 CFR 108.17 and 14 CFR 129.26)
|